Global Certification Corp.
Date of Issue: SEP.13,2007
Report No:F790506
Page15/16
5. MODIFICATION LIST FOR EMC COMPLYING TEST
The modification is solely made by the applicant.
Appendix
Appendix A: Summary of Test Result
Appendix B: The test photograph of EUT
Appendix C: The Detail Photograph of EUT
Appendix A: Summary of Test Result
**** EMC Test Result: The EUT has been pass the all measurements. ****
The uncertainty is calculated in accordance with CISPR16-4-2, the total uncertainty for this test is as
follows:
Uncertainty of Conducted Emission Measurement
Contribution
Probability Distribution
150KHz – 30MHz
Receiver reading Normal (k=2) ±0.2
Cable loss Normal (k=2)
±0.2
AMN insertion loss Rectangular
±0.2
RCV/SPA specification Rectangular
±0.9
combined standard uncertainty Ue(y) normal
±1.0
Measuring uncertainty for a level of confidence of 95%
U=2Ue(y)
normal (k=2)
±2.0
Uncertainty of Radiated Emission Measurement
Contribution
Probability Distribution
30MHz~1GHz
Receiver reading Normal (k=2)
±0.5
Cable loss calibration Normal (k=2)
±0.3
Antenna factor calibration Rectangular
±1.5
Pre Amplifier Gain calibration Rectangular
±0.5
RCV/SPA specification Rectangular
±0.9
combined standard uncertainty Ue(y) normal
±1.1
Measuring uncertainty for a level of confidence of 95%
U=2Ue(y)
normal (k=2)
±2.2