Release Notes 13
8. Log in to RAIDar on controller B as a Manage user with the correct password.
The message area warns you that a code load is in progress. In this case, you can
ignore the warning.
9. Select Manage > Update Software > Controller Software
10. Click Browse and locate
neptunesw-J200R05-01.bin.
11. Click Load Software Package File
When processing is complete, the page shows the version of each software
component that will be installed.
12. Click Proceed With Code Update.
The update may take up to 10 minutes to complete. When the process is complete, a
message tells you that you have been logged out because you have just loaded new
code.
13. Power off both controllers.
14. After 20 seconds, power on both controllers.
15. After two minutes, log in to RAIDar on controller A as a Manage user with the
correct password.
■ If the login page is not found, continue with “Resetting the IP Addresses”.
■ If the login page is displayed, continue with “Completing the Upgrade” on
page 16.
Resetting the IP Addresses
If you cannot remotely access the controller IP addresses, they might have changed.
Unless you know what the IP addresses are, you will not be able to log in remotely.
The command-line interface (CLI) embedded in each controller module enables you
to access the system using RS-232 communication and terminal emulation software.
Use the CLI commands described in the steps below to set the IP address for the
Ethernet management port on each controller module.
1. Refer to the list of network parameters that you recorded in Step 3 of “Recording IP
Addresses” on page 10. You need the IP address, subnet mask, and gateway IP
address for controller A and controller B.
2. Use the provided micro-DB9 serial cable to connect the management host to the
CLI port on controller A.