22.19
InForm OS Version 2.2.4 Command Line Interface Reference
When the power supply is switched off, it will be reported as Off through the showcage -d
command as well as a degraded alert being posted. The following is a sample of the output:
NOTES
The power supply model, as shown in the Model column of the showcage –d output, is set by
service personnel using the
setcage command, as described in setcage on page 21.14.
cli% showcage -d cage3 | egrep -i 'Power|\<ps'
Power Supply Info State Fan State AC Model
ps0 OK OK OK MAG
ps1 Off OK OK MAG
ps2 Failed OK Failed MAG
ps3 OK OK OK MAG
cli% showalert | grep Cage\ 3
Message : Cage 3, Power Supply 1 Degraded (Power Supply Off)
Message : Cage 3, Power Supply 2 Failed (Power Supply Failed, Power
Supply AC Failed)
cli%