15-4 Troubleshooting operational problems
System status remains “Faulty”
Standard 1.0 Option 11 EC Installation and Maintenance Guide November 1999
System status remains “Faulty”
Troubleshooting when
the system status
remains “Faulty”
If a Faulty status occurs during startup, refer to Chapter 16,
“Troubleshooting startup problems.” If the administration
terminal indicates that the system status is faulty despite a
successful startup, follow these steps.
Step Action
1 Check the SEER printout for related messages.
2 Take action appropriate for the SEER messages as
described in the
Meridian Mail
Maintenance
Messages (SEERS) Guide
(NTP 555-7001-510).
3 Courtesy down the system, then reactivate the
system.
Note: Refer to the
System Administration Guide
(NTP 555-7001-301) for instructions on how to
courtesy down and reactivate the system.
4 Verify that the Application Module Link cabling from
the EC 11 to the Meridian 1 Option 11 is connected
and secured.
5 Ensure correct database programming for the AML
dataport in Meridian Mail.
6 Replace the Enhanced MMP40 or MMP40 CPU
card and the Utility card one at a time.
7 Determine whether Node 1 or Node 2 shows Faulty
or OutOfService status. If so, then
a. check for card cage problems
b. check for a disk subsystem problem
c. check if Meridian Mail is communicating with
SCSI address 0, 1, or 2
8 Determine whether any of the voice cards shows
Faulty or OutOfService status. If so, then
a. disable the card (For detailed instructions on
disabling the card, refer to the
System
Administration Guide
[NTP 555-7001-301].)
b. perform OutOfService diagnostics
c. reenable the card
Przeglądanie stron 217